Recordeu que es poden pujar les aportacions als sexennis de l'ANECA al repositori institucional, sense necessitat d’esperar que s’òbriga la convocatòria. Fer-ho amb antelació pot evitar imprevistos tècnics i facilitar la gestió. Articles: S’han de dipositar mitjançant la passarel·la GREC/RODERIC. Llibres, capítols de llibre o dades de recerca: S’han de dipositar directament a través de RODERIC. ________________________________________ Recordad que se pueden subir las aportaciones a los sexenios de la ANECA al repositorio institucional, sin necesidad de esperar a que se abra la convocatoria. Hacerlo con tiempo puede evitar imprevistos técnicos y facilitar la gestión. Artículos: Deben depositarse mediante la pasarela GREC/RODERIC. Libros, capítulos de libro o datos de investigación: Deben depositarse directamente a través de RODERIC
Journal article Add to Favorites
HandleDOI

Intraobserver Reliability of Two-Dimensional Ultrasound Measurements of the Linea Alba in Parous Women During Different Abdominopelvic Exercises

Loading...
Thumbnail Image

Publication Date

Reading Date

Journal Title

Journal ISSN

Volume Title

Directors

Abstract

Objective To assess the intraobserver reliability of Diastasis Recti Abdominis (DRA) measurement by ultrasonography during four specific abdominopelvic exercises, evaluating interrecti distance, Linea Alba (LA) thickness, and distortion index in parous women. Methods Fifty-four parous women were assessed using ultrasound imaging for the LA. Four exercises were evaluated: crunch, abdominal drawing-in maneuver, pelvic floor muscle contraction, and one exercise based on the de Gasquet Method. Each exercise was performed three times. The ultrasound probe was placed 3 cm above and 2 cm below the umbilicus. Interrecti distance (IRD), distortion index, and LA thickness were measured and analyzed using ImageJ software by independent researchers. Intraobserver reliability was evaluated using the intraclass correlation coefficient (ICC) with a 95% confidence interval. Results ICC values for the IRD ranged from 0.84 to 0.99 for the four exercises. The distortion index showed moderate to high reliability (ICC: 0.77-0.98), while LA thickness also demonstrated moderate to high reliability (ICC: 0.75-0.98). Conclusion The results demonstrate the reliability of ultrasound in measuring key parameters, including LA thickness, distortion, and IRD in women with DRA during various exercises. As a non-invasive tool, it supports evidence-based interventions in postpartum recovery and clinical practice.

Bibliographic reference

Publisher

Signature

Full item page

Other versions

Metrics

Export
endnotezotero
Cite
Citations
0 citations in
Share