Recordeu que es poden pujar les aportacions als sexennis de l'ANECA al repositori institucional, sense necessitat d’esperar que s’òbriga la convocatòria. Fer-ho amb antelació pot evitar imprevistos tècnics i facilitar la gestió. Articles: S’han de dipositar mitjançant la passarel·la GREC/RODERIC. Llibres, capítols de llibre o dades de recerca: S’han de dipositar directament a través de RODERIC. ________________________________________ Recordad que se pueden subir las aportaciones a los sexenios de la ANECA al repositorio institucional, sin necesidad de esperar a que se abra la convocatoria. Hacerlo con tiempo puede evitar imprevistos técnicos y facilitar la gestión. Artículos: Deben depositarse mediante la pasarela GREC/RODERIC. Libros, capítulos de libro o datos de investigación: Deben depositarse directamente a través de RODERIC
Journal article Add to Favorites
HandleDOI

A study of Type B uncertainties associated with the photoelectric effect in low-energy Monte Carlo simulations

Loading...
Thumbnail Image

Publication Date

Reading Date

Journal Title

Journal ISSN

Volume Title

Directors

Keywords

Abstract

Purpose. To estimate Type B uncertainties in absorbed-dose calculations arising from the different implementations in current state-of-the-art Monte Carlo (MC) codes of low-energy photon cross-sections (<200 keV). Methods. MC simulations are carried out using three codes widely used in the low-energy domain: PENELOPE-2018, EGSnrc, and MCNP. Three dosimetry-relevant quantities are considered: mass energy-absorption coefficients for water, air, graphite, and their respective ratios; absorbed dose; and photon-fluence spectra. The absorbed dose and the photon-fluence spectra are scored in a spherical water phantom of 15 cm radius. Benchmark simulations using similar cross-sections have been performed. The differences observed between these quantities when different cross-sections are considered are taken to be a good estimator for the corresponding Type B uncertainties. Results. A conservative Type B uncertainty for the absorbed dose (k = 2) of 1.2%-1.7% (<50 keV), 0.6%-1.2% (50-100 keV), and 0.3% (100-200 keV) is estimated. The photon-fluence spectrum does not present clinically relevant differences that merit considering additional Type B uncertainties except for energies below 25 keV, where a Type B uncertainty of 0.5% is obtained. Below 30 keV, mass energy-absorption coefficients show Type B uncertainties (k = 2) of about 1.5% (water and air), and 2% (graphite), diminishing in all materials for larger energies and reaching values about 1% (40-50 keV) and 0.5% (50-75 keV). With respect to their ratios, the only significant Type B uncertainties are observed in the case of the water-to-graphite ratio for energies below 30 keV, being about 0.7% (k = 2). Conclusions. In contrast with the intermediate (about 500 keV) or high (about 1 MeV) energy domains, Type B uncertainties due to the different cross-sections implementation cannot be considered subdominant with respect to Type A uncertainties or even to other sources of Type B uncertainties (tally volume averaging, manufacturing tolerances, etc). Therefore, the values reported here should be accommodated within the uncertainty budget in low-energy photon dosimetry studies.

Bibliographic reference

Publisher

Signature

Collections:

Full item page

Other versions

Document Viewer

Select a file:
Reload