Recordeu que es poden pujar les aportacions als sexennis de l'ANECA al repositori institucional, sense necessitat d’esperar que s’òbriga la convocatòria. Fer-ho amb antelació pot evitar imprevistos tècnics i facilitar la gestió. Articles: S’han de dipositar mitjançant la passarel·la GREC/RODERIC. Llibres, capítols de llibre o dades de recerca: S’han de dipositar directament a través de RODERIC. ________________________________________ Recordad que se pueden subir las aportaciones a los sexenios de la ANECA al repositorio institucional, sin necesidad de esperar a que se abra la convocatoria. Hacerlo con tiempo puede evitar imprevistos técnicos y facilitar la gestión. Artículos: Deben depositarse mediante la pasarela GREC/RODERIC. Libros, capítulos de libro o datos de investigación: Deben depositarse directamente a través de RODERIC
Journal article Add to Favorites
HandleDOI

Shear bond strength of three different metal bracket base designs on human premolars: An in vitro comparative study

Loading...
Thumbnail Image

Publication Date

Reading Date

Journal Title

Journal ISSN

Volume Title

Directors

Keywords

Abstract

BACKGROUND: Adequate bracket-enamel bonding is critical to prevent detachment during orthodontic treatment and minimize any potential delay in results. The aim was to compare the shear bond strength of three metal bracket base designs: laser-structured base, mesh base, and retention grooves base. MATERIAL AND METHODS: In this experimental in vitro study, 54 human premolars were immersed for one week in 0.1% thymol solution, then placed in distilled water with weekly replacement until the start of the study. The premolars were cemented with brackets of varying base designs: A. Discovery® Smart (laser structured), B. Mini Master® Series (base with mesh), and C. Roth Max (base with retention grooves). All brackets were cemented using TransbondTM XT. A universal testing machine was used to evaluate the shear bond strength at a crosshead speed of 0.75 mm/min. Welch's one-factor ANOVA with robust variance and Tukey's post hoc test were used to compare means, with a significance level of p<0.05. RESULTS: The average shear bond strength values were for the bracket with laser-structured base (14.78 ± 5.79 MPa), the bracket with mesh base (9.64 MPa ± 2.54 MPa) and the bracket with retention groove base (15.38 MPa ± 2.67 MPa). It was found that brackets with mesh bases had significantly lower shear bond strength than brackets with laser-structured bases (p=0.001) and brackets with retention grooves bases (p<0.001). No significant differences were observed between the latter two types of brackets (p = 0.893). CONCLUSIONS: The bracket base design influenced in vitro shear bond strength with significantly higher values observed for Roth Max and Discovery® Smart brackets compared to Mini Master® Series brackets. Key words:Shear strength, laser-structured bracket, bracket with mesh base, bracket with retention groove base.

Bibliographic reference

Publisher

Medicina Oral S.L

Signature

Full item page

Other versions

Document Viewer

Select a file:
Reload