Recordeu que es poden pujar les aportacions als sexennis de l'ANECA al repositori institucional, sense necessitat d’esperar que s’òbriga la convocatòria. Fer-ho amb antelació pot evitar imprevistos tècnics i facilitar la gestió. Articles: S’han de dipositar mitjançant la passarel·la GREC/RODERIC. Llibres, capítols de llibre o dades de recerca: S’han de dipositar directament a través de RODERIC. ________________________________________ Recordad que se pueden subir las aportaciones a los sexenios de la ANECA al repositorio institucional, sin necesidad de esperar a que se abra la convocatoria. Hacerlo con tiempo puede evitar imprevistos técnicos y facilitar la gestión. Artículos: Deben depositarse mediante la pasarela GREC/RODERIC. Libros, capítulos de libro o datos de investigación: Deben depositarse directamente a través de RODERIC
Journal article Add to Favorites
HandleDOI

The effect of anesthetic eye drop instillation on the distribution of corneal thickness

Loading...
Thumbnail Image

Publication Date

Reading Date

Journal Title

Journal ISSN

Volume Title

Directors

Abstract

Purpose: To address the effect of topical instillation of oxybuprocaine on the relative distribution of corneal thickness (CT) in young healthy subjects. Methods: Prospective study involving 30 eyes of 30 emmetropic subjects (24 6 3 years). Corneal thickness measurements were carried out before and 3 minutes after the instillation of oxybuprocaine 4% using slit-scanning corneal topography (Orbscan topography system II). No acoustic correction factor was applied. The mean of 5 consecutive Orbscan measurements was obtained at the center and 3 mm from the visual axis in the temporal, superior, nasal, and inferior hemimeridians. Results: No significant mean differences were found at any corneal location after anesthesia (P >. 0.05). The difference between the baseline values obtained of the central, superior, inferior, nasal, and temporal cornea and those obtained after anesthesia ranged from 215 to 16 microns, from 219 to 32 microns, from 214 to 24 microns, from 220 to 33 microns, and from 231 to 18 microns, respectively. The maximum paracentral CT was never found at the temporal location before anesthesia, whereas it was never found at the inferior location after anesthesia. The minimum paracentral CT was never found in the superior location after anesthesia. Conclusions: Topical anesthetic eye drops induce CT increases and decreases at each corneal location; however, the differences are not significant. Nevertheless, a change in the location of the minimum and maximum paracentral thickness occurs in some individuals after corneal anesthesia.

Bibliographic reference

Publisher

Signature

Full item page

Other versions