Recordeu que es poden pujar les aportacions als sexennis de l'ANECA al repositori institucional, sense necessitat d’esperar que s’òbriga la convocatòria. Fer-ho amb antelació pot evitar imprevistos tècnics i facilitar la gestió. Articles: S’han de dipositar mitjançant la passarel·la GREC/RODERIC. Llibres, capítols de llibre o dades de recerca: S’han de dipositar directament a través de RODERIC. ________________________________________ Recordad que se pueden subir las aportaciones a los sexenios de la ANECA al repositorio institucional, sin necesidad de esperar a que se abra la convocatoria. Hacerlo con tiempo puede evitar imprevistos técnicos y facilitar la gestión. Artículos: Deben depositarse mediante la pasarela GREC/RODERIC. Libros, capítulos de libro o datos de investigación: Deben depositarse directamente a través de RODERIC

Effect of alloy type and casting technique on the fracture strength of implant-cemented structures

dc.contributor.authorCastillo de Oyagüe, Raqueles
dc.contributor.authorOsorio Ruiz, R.es
dc.contributor.authorLynch, Christopher D.es
dc.contributor.authorGilmour, Alanes
dc.contributor.authorToledano Pérez, Manueles
dc.date.accessioned2017-07-26T11:20:31Z
dc.date.available2017-07-26T11:20:31Z
dc.date.issued2011es
dc.description.abstractObjectives: To evaluate the influence of alloy type and casting procedure on the fracture strength (FS) of metallic frameworks for implant-supported fixed prostheses. Study design: Thirty three-unit structures for lower posterior bridges were waxed-up and randomly assigned to two groups (n=15) according to alloy type and casting technique: Group 1 (C): cobalt-chromium cast in a centrifugal machine (TS1, Degussa-Hüls); Group 2 (T): titanium cast in a pressure-differential device (Cyclarc II, Morita). Each structure was cemented onto two prefabricated abutments under a constant seating pressure. After 6 months of water aging, samples were loaded in a static universal testing machine (EFH/5/FR, Microtest) until fracture. Axial compressive loads were applied at the central fossa of the pontics. FS data were recorded and surface topography of the fractured connectors was SEM-analyzed. A Chi-Square test was performed to assess the dependence of pores on the alloy type and casting procedure. ANOVA and Student-Newman-Keuls (SNK) tests were run for FS comparisons (p<0.05). Results: One third of the C structures showed pores inside the fractured connectors. T frameworks demonstrated higher FS than that of C specimens exhibiting pores (p=0.025). C samples containing no pores recorded the greatest mean FS (p<0.001). Conclusions: Fracture strength of metallic frameworks depended on the alloy type and casting procedure. Cobalt-chromium casts often registered pores inside the connectors, which strongly decreased the fracture resistance. An accurate casting of titanium with a pressure-differential system may result in the most predictable technique under the tested experimental conditions. © Medicina Oral S. L.es
dc.description.provenanceMade available in DSpace on 2017-07-26T11:20:31Z (GMT). No. of bitstreams: 1 5827301.pdf: 6249128 bytes, checksum: 67d9ec39ced8bf689b1659a8cf449af1 (MD5) Previous issue date: 2011en
dc.identifier.citationCastillo de Oyagüe, Raquel ; Osorio Ruiz, R. ; Lynch, Christopher D. ; Gilmour, Alan ; Toledano Pérez, Manuel. Effect of alloy type and casting technique on the fracture strength of implant-cemented structures. En: Medicina oral, patología oral y cirugía bucal. Ed. inglesa, 16 4 2011: 29-es
dc.identifier.doi10.4317/medoral.16.e619es
dc.identifier.urihttp://hdl.handle.net/10550/60131
dc.language.isoeng
dc.rights.accessRightsopen access
dc.subject.unescoUNESCO::CIENCIAS MÉDICASes
dc.titleEffect of alloy type and casting technique on the fracture strength of implant-cemented structureses
dc.typejournal article
dc.type.hasVersionVoRes_ES

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
5827301.pdf
Size:
5.96 MB
Format:
Adobe Portable Document Format