Optical performance studies of an all-polymer air-core scintillation dosemeter for brachytherapy
| dc.contributor.author | Boughaba, Nor El Houda | |
| dc.contributor.author | Bouzid, Boualem | |
| dc.contributor.author | Yahlali Haddou, Nadia | |
| dc.date.accessioned | 2026-04-22T09:05:32Z | |
| dc.date.available | 2026-04-22T09:05:32Z | |
| dc.date.issued | 2026 | |
| dc.date.updated | 2026-04-22T09:05:36Z | |
| dc.description.abstract | Plastic scintillation dosemeters have gained significant interest for invivo dosimetry in high-dose rate brachytherapy (BT) due to their favourable dosimetric properties. However, their clinical utility is limited by Cerenkov radiation, which can contribute over 50% of the signal, depending on the source position. The current dosemeter based on silica air-core (AC) light-guide was proven to be highly accurate; however, its high light loss and its mechanical rigidity limit its use for invivo BT dosimetry with flexible applicators. In the present work, a novel flexible all-polymer dosemeter with silver-coated polytetrafluoroethylene (Ag-PTFE) light-guide was built and compared to a solid-core light-guide dosemeter (standard dosemeter), using Geant4 Application for Tomographic Emission simulations. A reduction of the Cerenkov noise in the signal of this AC dosemeter was found below 0.3%, independently of the source position. On the other hand, the light collection efficiency was found to be 40% smaller than in the standard dosemeter. We show how it is possible to further reduce this difference to 20% and discuss the optimal design of this all-polymer Cerenkov-free dosemeter. | |
| dc.description.provenance | Made available in DSpace on 2026-04-22T09:05:32Z (GMT). No. of bitstreams: 1 180985.pdf: 1547001 bytes, checksum: 968fb8aa6063117313e4ff7e5b2aae6a (MD5) Previous issue date: 2026 | en |
| dc.identifier.doi | 10.1093/rpd/ncaf147 | |
| dc.identifier.idgrec | 180985 | |
| dc.identifier.issn | 0144-8420 | |
| dc.identifier.uri | https://hdl.handle.net/10550/125882 | |
| dc.language.iso | eng | |
| dc.relation.ispartof | Radiation Protection Dosimetry, 2025, vol. 202, num. 2, p. 97-101 | |
| dc.rights.accessRights | open access | |
| dc.source | Boughaba, Nor El Houda Bouzid, Boualem Yahlali Haddou, Nadia 2025 Optical performance studies of an all-polymer air-core scintillation dosemeter for brachytherapy Radiation Protection Dosimetry 202 2 97 101 | |
| dc.subject | física | |
| dc.title | Optical performance studies of an all-polymer air-core scintillation dosemeter for brachytherapy | |
| dc.type | journal article |