Recordeu que es poden pujar les aportacions als sexennis de l'ANECA al repositori institucional, sense necessitat d’esperar que s’òbriga la convocatòria. Fer-ho amb antelació pot evitar imprevistos tècnics i facilitar la gestió. Articles: S’han de dipositar mitjançant la passarel·la GREC/RODERIC. Llibres, capítols de llibre o dades de recerca: S’han de dipositar directament a través de RODERIC. ________________________________________ Recordad que se pueden subir las aportaciones a los sexenios de la ANECA al repositorio institucional, sin necesidad de esperar a que se abra la convocatoria. Hacerlo con tiempo puede evitar imprevistos técnicos y facilitar la gestión. Artículos: Deben depositarse mediante la pasarela GREC/RODERIC. Libros, capítulos de libro o datos de investigación: Deben depositarse directamente a través de RODERIC

The effect of surface treatment with Er:YAG laser on shear bond strength of orthodontic brackets to fi ber-reinforced composite

dc.contributor.authorDehghani, Mahboobees
dc.contributor.authorAhrari, Farzanehes
dc.date.accessioned2015-01-20T09:26:26Z
dc.date.available2015-01-20T09:26:26Z
dc.date.issued2014es
dc.description.abstractObjectives: This study aimed to investigate the effect of surface treatment with Er:YAG laser on shear bond streng- th (SBS) of orthodontic brackets to fi ber-reinforced composite (FRC). Study Design: Ninety human premolars were randomly divided into six groups of 15. FRC bars were bonded to the teeth with a fl owable composite (FC) and then underwent following treatments. In group 1 no further treatment was performed. In group 2 the FRC surfaces were covered by FC. An Er:YAG laser was employed to treat FRCs in groups 3 ( 200 mJ/10 Hz) and 4 (300 mJ/15 Hz). The FRC strips in groups 5 and 6 were fi rst covered by FC and then irradiated with Er:YAG laser at 200 mJ/10 Hz (group 5) or 300 mJ/15 Hz (group 6). Stainless steel brackets were bonded to FRCs using a light-cure adhesive system. After 24 hours, the samples were tested for SBS and the adhesive remnant index (ARI) scores were determined. Results: There was a signifi cant difference in SBS among the study groups (P <0.001). Pairwise comparisons in- dicated that SBS was signifi cantly lower in group 1 compared to all other groups (p<0.05) except group 2. Bond strength in group 6 was signifi cantly greater than all the study groups (p<0.05) except group 5. No signifi cant di- fference was found in ARI scores among the groups. Conclusions: Covering the FRC surface by a layer of fl owable composite and then application of Er:YAG laser at 300 mJ/15 Hz could be recommended to increase bond strength of orthodontic attachments to FRC.en_US
dc.description.provenanceMade available in DSpace on 2015-01-20T09:26:26Z (GMT). No. of bitstreams: 1 379-383.pdf: 393342 bytes, checksum: 230d62c2e86a674f99d2d422221a2873 (MD5) Previous issue date: 2014en
dc.identifier.citationDehghani, Mahboobe ; Ahrari, Farzaneh. The effect of surface treatment with Er:YAG laser on shear bond strength of orthodontic brackets to fi ber-reinforced composite. En: Journal of Clinical and Experimental Dentistry, 2014, Vol. 6, No. 4: 379-383es
dc.identifier.urihttp://hdl.handle.net/10550/41333
dc.language.isoeng
dc.rights.accessRightsopen access
dc.subjectOdontologíaes
dc.subjectCiencias de la saludes
dc.subject.unescoUNESCO::CIENCIAS MÉDICASes
dc.titleThe effect of surface treatment with Er:YAG laser on shear bond strength of orthodontic brackets to fi ber-reinforced compositees
dc.typejournal article
dc.type.hasVersionVoRes_ES

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
379-383.pdf
Size:
384.12 KB
Format:
Adobe Portable Document Format