Recordeu que es poden pujar les aportacions als sexennis de l'ANECA al repositori institucional, sense necessitat d’esperar que s’òbriga la convocatòria. Fer-ho amb antelació pot evitar imprevistos tècnics i facilitar la gestió. Articles: S’han de dipositar mitjançant la passarel·la GREC/RODERIC. Llibres, capítols de llibre o dades de recerca: S’han de dipositar directament a través de RODERIC. ________________________________________ Recordad que se pueden subir las aportaciones a los sexenios de la ANECA al repositorio institucional, sin necesidad de esperar a que se abra la convocatoria. Hacerlo con tiempo puede evitar imprevistos técnicos y facilitar la gestión. Artículos: Deben depositarse mediante la pasarela GREC/RODERIC. Libros, capítulos de libro o datos de investigación: Deben depositarse directamente a través de RODERIC

Evaluation of the biocompatibility of experimentally manufactured portland cement: an animal study

dc.contributor.authorKoçak, Sibeles
dc.contributor.authorErten, Hülyaes
dc.contributor.authorBaris, Emrees
dc.contributor.authorAlaçam, Tayfunes
dc.date.accessioned2014-05-22T10:05:37Z
dc.date.available2014-05-22T10:05:37Z
dc.date.issued2014es
dc.description.abstractObjectives: The purpose of this study was to evaluate the biocompatibility of MTA and the experimentally manufactured portland cement (EMPC). Study design: Twenty one Sprague Dawley (SD) rats were allocated to testing of three groups. Group I and Group II included ProRoot MTA and the EMPC. The materials were mixed with distilled water and placed in polyethylene tubes. The tubes were implanted subcutaneously in the dorsal region of the animals. Group III served as control; the implanted polyethylene tubes remained empty. At 7, 14, and 28 days after the implantation, the animals were sacrificed and the implants were removed with the surrounding tissues. The specimens were prepared for histological examination to evaluate the inflammatory response. Results: No significant difference was found between tissue reactions against the tested materials (p>0.05). Also, control group showed similar results(p>0.05). Conclusions: Results suggest that the EMPC has the potential to be used in clinical conditions in which ProRoot MTA is indicated. MTA and the EMPC show comparable biocompatibility when evaluated in vivo. Although the results are supportive for the EMPC, more studies are required before the safe clinical use of the EMPC.en_US
dc.description.provenanceMade available in DSpace on 2014-05-22T10:05:37Z (GMT). No. of bitstreams: 1 17-21.pdf: 435765 bytes, checksum: 8e73b73341e5d5366e2dd2ef3c0cb02d (MD5) Previous issue date: 2014en
dc.identifier.citationKoçak, Sibel ; Erten, Hülya ; Baris, Emre ; Alaçam, Tayfun. Evaluation of the biocompatibility of experimentally manufactured portland cement: an animal study. En: Journal of Clinical and Experimental Dentistry, 2014, Vol. 6, No. 1: 17-21es
dc.identifier.urihttp://hdl.handle.net/10550/35368
dc.language.isoeng
dc.rights.accessRightsopen access
dc.subjectOdontologíaes
dc.subjectCiencias de la saludes
dc.subject.unescoUNESCO::CIENCIAS MÉDICASes
dc.titleEvaluation of the biocompatibility of experimentally manufactured portland cement: an animal studyes
dc.typejournal article
dc.type.hasVersionVoRes_ES

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
17-21.pdf
Size:
425.55 KB
Format:
Adobe Portable Document Format