Recordeu que es poden pujar les aportacions als sexennis de l'ANECA al repositori institucional, sense necessitat d’esperar que s’òbriga la convocatòria. Fer-ho amb antelació pot evitar imprevistos tècnics i facilitar la gestió. Articles: S’han de dipositar mitjançant la passarel·la GREC/RODERIC. Llibres, capítols de llibre o dades de recerca: S’han de dipositar directament a través de RODERIC. ________________________________________ Recordad que se pueden subir las aportaciones a los sexenios de la ANECA al repositorio institucional, sin necesidad de esperar a que se abra la convocatoria. Hacerlo con tiempo puede evitar imprevistos técnicos y facilitar la gestión. Artículos: Deben depositarse mediante la pasarela GREC/RODERIC. Libros, capítulos de libro o datos de investigación: Deben depositarse directamente a través de RODERIC
Doctoral thesis Add to Favorites

Characterization of PETit: a TOF-PET prototype based on liquid xenon

Loading...
Thumbnail Image

Publication Date

Reading Date

2026-09-22

Journal Title

Journal ISSN

Volume Title

Abstract

Positron emission tomography (PET) is a medical imaging technique widely used in clinical diagnosis, especially in oncology, neurology, and cardiology. Its operation is based on the coincidence detection of the two 511 keV gamma photons produced after the annihilation of a positron emitted by a radiotracer with an electron from the surrounding medium. In order to obtain high-quality images, PET systems require detectors with excellent temporal, energy, and spatial performance. The final performance of the system strongly depends on the scintillation materials and photosensors employed. Liquid xenon presents very attractive properties for this type of application. Among its advantages is a high light yield, generating approximately 30,000 photons per 511 keV interaction, which enables good energy resolution. In addition, it possesses a fast scintillation component of only 2.2 ns, enabling excellent temporal performance and time-of-flight applications. Another important characteristic is that liquid xenon is transparent to its own scintillation light, allowing light collection. Furthermore, since it is in liquid form, it can be continuously purified through recirculation and filtration systems, achieving a homogeneous response throughout the detector. However, liquid xenon also presents limitations. The main one is its relatively low photodetection fraction, only 22%, as well as its attenuation length for 511 keV photons, which requires the use of thicker detectors to achieve efficiencies comparable to other materials. The PETit prototype was developed with the aim of studying the feasibility of liquid xenon as a detector medium for PET applications and characterizing its temporal and energy responses.

Description

The work in this thesis has been carried out at the Instituto de Física Corpuscular (IFIC), affiliated with the Universitat de València and CSIC with the FPI grant PRE2021-097277

Bibliographic reference

Publisher

Signature

Collections:

Full item page

Other versions

Export
endnotezotero
Cite
Citations
plumx
0 citations in
Google Scholar
| Other documents of authorship
Share

Document Viewer

Select a file:
Reload