dc.contributor.author |
Paul, Nayana |
es |
dc.contributor.author |
Raghavendra Swamy, K. N |
es |
dc.contributor.author |
Dhakshaini, M. R |
es |
dc.contributor.author |
Sowmya, Sanjukta |
es |
dc.contributor.author |
Ravi, M. B |
es |
dc.date.accessioned |
2020-10-21T09:18:29Z |
|
dc.date.available |
2020-10-21T09:18:29Z |
|
dc.date.issued |
2020 |
es |
dc.identifier.uri |
https://hdl.handle.net/10550/75980 |
|
dc.description.abstract |
The purpose of this in vivo study was to compare the marginal and internal gap widths of monolithic zirconia crowns fabricated by CAD/CAM technique and metal-ceramic crowns fabricated by conventional technique. 10 participants needing a single restoration were selected. Zirconia crowns using CAD/CAM technology (Group A) (n=10) and metal-ceramic crowns (Group B) (n=10) using lost wax casting technique were fabricated for each selected tooth. The marginal and internal gaps of crowns were recorded using a replica technique with light body silicone material stabilized with a regular set putty. Each replica was sectioned buccolingually and mesiodistally and then evaluated at five pre-determined sites. The points measured were PM for marginal gap, PA for axial gap, PAO for axio-occlusal transition gap and PO and PCO for occlusal gaps using a stereomicroscope at 30× magni?cation. The Paired Sample (t) test was used to detect significant differences between the two groups in terms of marginal and internal fit (?= 0.05). The mean for the marginal gap was 77.42?m (±39.5?m) for Group A compared with 95.86?m (±55.12?m) for Group B. Mean values for internal gap was 87.24 (±21.7 µm) for Group A and 132.91 µm (± 50.63 µm) for Group B. Significant differences were observed between both the groups for marginal (p=.010) and internal (p=.000) fit. The CAD/CAM fabricated zirconia crowns demonstrated a better accuracy of fit when compared to metal-ceramic crowns fabricated by conventional technology. |
es |
dc.source |
Paul, Nayana ; Raghavendra Swamy, K. N ; Dhakshaini, M. R ; Sowmya, Sanjukta ; Ravi, M. B. Marginal and internal fit evaluation of conventional metal-ceramic versus zirconia CAD/CAM crowns. En: Journal of Clinical and Experimental Dentistry, 12 1 2020: 31-37 |
es |
dc.title |
Marginal and internal fit evaluation of conventional metal-ceramic versus zirconia CAD/CAM crowns |
es |
dc.type |
journal article |
es_ES |
dc.subject.unesco |
UNESCO::CIENCIAS MÉDICAS |
es |
dc.identifier.doi |
10.4317/jced.55946 |
es |
dc.type.hasVersion |
VoR |
es_ES |